Temperature Controller KT-360

Home >>  Prodcut Catalogue >>  Controller for Freezing

Temperature Controller KT-360
Brand Name: Neutral or KingTill
Brief Info: Three relays, Sensor: NTC, 2 sensors, 2m (L)

Product Description

Temperature Controller KT-360

Function:
Temperature Control, Manual, automatic defrost, Evap.Fan Control,
Defrost by electric heater or hot gas, Time and Temp. Setting to end defrost
 
Technical Parameter:
Power supply: 230VAC
Temperature sensor: NTC, 2 sensors, 2m (L)
Temperature measuring range: -45℃ ~ 150℃
 -Accuracy: ±1.0℃(±1.8℉)
 -Resolution: 0.1(-19.9℃ ~ 99.9℃)
Temperature controlling range: -45℃ ~ +45℃,  Default : 0℃(32.0℉)
Dimension: 77(L) ×35(W)×60(D)mm
Mounting Size: 71(L)×29(W)mm
Operating environment:
 -Temperature: -10℃ ~ 60℃, Relative Humidity: 20% ~ 90% (No condensing)
Relay output contact capacity:
 Compressor: N.O. 16A/250VAC
 Defrost:          N.O. 10A/250VAC
 Evap.Fan:      N.O. 5A/250VAC

 Menu:

Paramete Function Set range Default
E1 Lower setpoint limit -45℃/-45℉~Set temp. -35℃/-31℉
E2 Higher setpoint limit Set temp.~45℃/113℉ 45℃/113℉
E3 Temp. Return Difference 1.0~20.0℃/1.8~36.0℉ 4.0℃/7.2℉
E4 Comp. start delay time 0~10Min 2Min
E5 Offset on room temp. -20.0~20.0℃/-36.0~36.0℉ 0
E6 Offset on evap. temp. -20.0~20.0℃/-36.0~36.0℉ 0
C1 Temperature unit 0=℃   1=℉ 0
F0 Defrost Mode 0=Electric heater  1=Hot gas 0
F1 Defrost Time 1~60Min 20Min
F2 Defrost Cycle 0~24Hr 6Hr
F3 Defrost termination temp. 0~30℃/32~86℉ 8℃/46℉
F4 Display during defrost 0=Normal display
1=Last value before defrost
0
F5 Fan operating function 0=Parallel with comp.
1=Continuous running except defrost
0
F6 Dripping time 0~30Min 2Min
F7 Fan operating function after defrost end 0=Temperature  1=Time 1
F8 Fan start-up temperature  after defrosting 0~10Min 2Min
F9 Fan start temperature after defrosting(evaporator) -30~30℃/-22~86℉ 5℃/41℉